Page 70
Unit Toggle Command
Using LEVITON PC Access Software, you can create programs to toggle any unit (1-511) from its current state to the opposite
state. When the program is executed, the unit will toggle to Off if the unit is currently in a non-off state (On, On for time, Level
1-100, Scene A-L, Dimmed Steps, Dimmed for time, Brightened Steps, or Brightened for time). When the program is executed,
the unit will toggle to On if the unit is currently Off.
Note: If a unit is currently timed (On for time, Dimmed for time, Brightened for time, or Off for time), when the toggle program
is executed, the unit will toggle to the opposite state and will defeat the timer.
This programming feature will simplify programming when using a button on a UPB, Compose, ALC, or RadioRA keypad to
toggle a light on and off with the push of a single button. For example:
WHEN FRONT FOYER SW1 PRESSED: FRONT FOYER TOGGLE
UPB Blink Command
Using LEVITON PC Access Software, you can create programs to blink any UPB device. If you are using HLC, you can not
blink an HLC room (i.e. the 1
st
or 9
th
unit in an HLC house code); you can however blink all of the devices within the HLC room,
individually.
When setting up the blink program, you will be asked to select one of four blink rates (0.25sec, 0.5sec, 1sec, or 2sec). When the
program is executed, the unit will begin blinking either indefinitely or for a specified period of time. If timed, the unit will return
to its previous state once the timer has expired.
Note: If a unit is currently timed (On for time, Dimmed for time, Brightened for time, or Off for time), when the blink program is
executed, the unit will begin blinking and the previous timer is disabled.
This programming feature will simplify programming when attempting to have a unit blink for a certain event such as an alarm.
For example:
WHEN ANY ALARM: HALLWAY LIGHT BLINK (1.00SEC) FOR 5 MINUTES
Timed Level Command
Using LEVITON PC Access Software, you can create programs to set the light level for a specified time. For example, when the
Front Door opens and it is dark outside, you can have the Foyer Light illuminate at 50% for 5 minutes with a single program line.
WHEN FRONT DOOR NOT READY &IF DARK: FOYER LIGHT TO 50% FOR 5 MINUTES
At the end of the timer duration, the light will return to its previous state. For example if the light level of the Foyer Light was at
25% prior to the Front Door opening, the light level will return to 25% five minutes after the door opens.
Program Security Commands
Press the 2 (SECURITY) key to arm and disarm the security system, or to bypass and restore an individual zone. The following
menu is displayed:
0=OFF 1=DAY 2=NIGHT
3=AWAY 4=VACATION
5=DAY INST 6=NIGHT DLY
8=BYPASS 9=RESTORE
Select (0-6) to arm the system into the desired mode or select the 8 key to Bypass and the 9 key to Restore a security zone. If area
arming is being used, the display will then prompt you for the area to be armed:
AREA
ENTER AREA 0=ALL
Enter the area number followed by the ' # ' key, or use the arrow keys to scroll through a list of areas. Press the ' # ' key first to
specify all areas.