3440-0241 Rev G
4
Value 0 - 9, A - D, Default: FF
.
52 Account Number 1 and 2 (2 Digit Entry)
When a reporting function is activated this account number
will identify the subscriber to the central station. In
memory location 52 will be the first two digits of the
account number and 52A will be the last two digits of the
first account number. 52B will be the first two digits of the
second account number and 52C will be the last two digits
.
Value 0000 - FFFF, Default: 0000.
Hex digits can be used in accounts numbers:
[AWAY] + 0 = A
[AWAY] + 1 = B
[AWAY] + 2 = C
[AWAY] + 3 = D
[AWAY] + 4 = E
[AWAY] + 5 = F
53 Receiver Formats for Receiver 1 and 2 (2 Digit Entry)
The first digit selects a format for Receiver number one.
The second digit selects a format for Receiver number two.
Many different types of central station receivers can accept
a multitude of formats. Naturally the format that “dumps”
the information the quickest is the most desirable. You
should consult with your central station to employ the
optimum format.
0 = SIA
1 = 10 PPS 4-1
2 = 10 PPS 4-1 extended
3 = 10 PPS 4-2
4 = 20 PPS 4-1
5 = 20 PPS 4-1 extended
6 = 20 PPS 4-2
0 - SIA
SIA is an FSK type reporting format that has all the
reporting codes encoded in the control panel software.
The reporting capabilities are simply enabled when any
reporting code other than 00 are programmed in. (A code
00 will disable the reporting capability). The information
sent is predetermined by the activation of a zone type :
EXAMPLES:
ZONE TYPE MESSAGE SENT
All Interior / Perimeter = Burglary + Zone Number
Fire zones = Fire + Zone Number
24 Hour = Burglary + Zone Number
Zone Restore (if used) = Restore + Zone Number
10 and 20 PPS formats
- The only difference between
these two formats is the speed and tone at which each
pulse of a digit in a message is transmitted. Both of these
formats will respond to 1400Hz or 2300Hz "handshake"
and "kiss off" tones. All of the 10 PPS formats are sent
using 1900Hz tones with a duration of 60 ms and a gap of
40ms for each pulse of a message digit. The 20PPS
formats are sent using 1800Hz tones with a duration of
30ms and a gap of 20ms for each pulse of a message
digit.
1 10 PPS 4-1
This format requires a four digit account number with a
single digit event code. A complete message consist of 2
identical rounds account and message digits. In the event
that you have been assigned a three digit account number,
the first digit in memory location 52 must be a zero.
Example: Account 123, program 0123.
The reporting codes in this format must be single digit,
therefore you must enter a zero in the first memory location
followed by the code number to be transmitted.
Example: code 3, program 03.
2 10 PPS 4-1 Extended
The digits are sent in the same manner as 4-1 but the
complete message consist of 2 rounds that will contain the
account number and the high digit of the message code.
This will be followed by two more rounds which will repeat
the high digit of the message code, in place of the account
number, and the low digit of the message code.
Example:
Message : 1234-F5
Transmitted : 2 rounds of 1234-F
2 rounds of FFFF-5
3 10 PPS 4-2
This is a format that is similar in reporting as 4-1 EXT.
With the exception that the reporting is sent as two
identical rounds of information.
4 - 20 PPS 4-1
All three are the same
5 - 20 PPS 4-1 Extended
as 10PPS except at a
6 - 20 PPS 4-2
faster
transmission speed.
Value 0 - 6, Default:: 1 - 1
53 A Anti-Jam Time
This is the amount of time required for the telephone company
to disconnect the phone line after the panel has hung up if it
was not "kissed" off on the first dialing attempt. Check with your
phone company for this value of time.
Value 00 - 99 seconds, Default: 15 seconds
.
53 B Line Type / Dial Attempts (2 Digit Entry)
The first digit indicates the telephone line type for dialing the
central station. A zero selects Rotary (pulse) dialing while any
digit 1 - 9 will select tone dialing.
Value 0 = Rotary; 1-9 = Touch-tone, Default: 0 (Rotary).
The second digit selects the number of dialing attempts to
report an event to the central station. If the communicator does
not receive a handshake and/or kissoff tone from the receiver, it
will disconnect and re-dial until the tone is heard or the
maximum number of attempts is reached.
Value 0 - 9, Default: 5. (minimum for UL 864)
53 C Delay Before Dial
(2 Digit Entry)
This function enables the capability of aborting the alarm
transmission if the panel is disarmed within the period of time
programmed in this memory location. This function is active on
burglary zones only. All 24 Hour type zones will send their data
immediately.
Value 00 - 99 seconds, Default: 00 seconds.
54 (A through G) Download Telephone Number
(Up to a 16 Digit Telephone Number)
This is a security function that when a call is initiated from a
Central Station download P.C. the panel will answer, recognize
the carrier tone from the modem, hang up the call, and call the
P.C. back. See memory location 48 for additional telephone
features
. Value 0 - D, Default: FF.