About Lutron HomeWorks
Lutron RadioRA uses a network of low voltage wires to communicate with and control HomeWorks lighting devices in your
home. Each switch or dimmer controls one lighting load in a HomeWorks system. They are used in place of standard light
switches and allow local control as well as remote control from any of the master keypads, an OmniPro II interface, or via
programming in the OmniPro II controller.
Master keypads are preprogrammed to provide control of the other dimmers and switches on the system. The OmniPro II listens
for when buttons are pressed on a master keypad and can run various programs when a button is pressed. OmniPro II can also be
programmed to simulate pressing a button on a master keypad.
GRAFIK Eye lighting controls and Remote Dimming Panels can be used to connect several lighting loads together in a room in
place of multiple switches. Scenes can be programmed in the GRAFIK Eye lighting control and Remote Dimming Panel to set a
group or room of lighting to preset levels. Programming in the OmniPro II allows for controlling the preprogrammed scenes in
the GRAFIK Eye lighting control or Remote Dimming Panel.
Lutron’s line of Sivoia Quiet Electronic Drive roller shades, roman shades, and draperies can be controlled with an OmniPro II
interface or via programming in the OmniPro II controller.
Lutron HomeWorks Format
OmniPro II groups devices by “House Code”, which consists of 16 consecutive unit numbers, starting at Unit 1. Each “House
Code” can be configured to a different lighting protocol format such as: Standard X-10, Extended X-10, Lightolier Compose,
UPB (open UPB format where you can use the programming capability in the OmniPro II controller to communicate with the
UPB network), Lutron RadioRA, LEVITON Lighting Control (HLC), CentraLite, Vizia RF Z-Wave, or Lutron HomeWorks.
Each Lutron HomeWorks switch, dimmer, master keypad, and GRAFIK Eye lighting control, Remote Dimming Panel, and Sivoia
shade and drapery control, hereafter referred to as HomeWorks devices, has its own Unit Number (1-256), which corresponds to
the HomeWorks Address of the device. Each HomeWorks device has an Address consisting of 3-5 numbers (00-99) separated by
a colon.
Using LEVITON PC Access Software 3.1 or later, enter the address for each Lutron HomeWorks device under the column
labeled “Address/Node ID” for each Unit Number to be controller by the OmniPro II controller
Controlling Lutron HomeWorks from an Omni Console
Use the Control menu to control lighting loads and HomeWorks devices. To enter the Control menu, from the top-level display
or from the main menu, press the 1 (CTRL) key on the console keypad.
OmniPro II will automatically display the first named unit.
To control a lighting load or HomeWorks device, select it from the list of units, and then press the ' # ' key.
Press 0 (OFF) to turn the selected lighting load off
Press 1 (ON) to turn the selected lighting load on
Press 2 (DIM) to dim the selected unit (1-9 steps, each step is 10% from its current level)
Press 3 (BRT) to brighten the selected unit (1-9 steps, each step is 10% from its current level)
Press 4 (LVL) to set the desired lighting level of the selected unit (0%-100%)
5 (RMP) is not used with Lutron HomeWorks
Press 9 (TIM) to time the selected unit (On, Off, Dim, Brighten)
Timed commands may be from 1-99 seconds, 1-99 minutes or 1-18 hours
Press # (STA) to see the status of the device.
Note: When a HomeWorks signal is received over the network, OmniPro II will automatically update the status of the device.