PC/VDT PROGRAMMING - POWER-UP MESSAGES
9-171
System 2 Installation / Programming Manual
Note: When you decide to utilize networking during the Initialization process, the System 2 sets aside
memory to engage this option now or at a later date. The Networking Options must be turned ON for
each unit to engage the use of multiple doors . Proceed to Option #13 to turn this Option ON.
The unit assigns networking for those customers who wish to add additional doors in the future, but do not
wish to clear memory and re-initialize the unit or re-program all the user codes.
Networking
Networking is the name given to the use of multiple System 2's linked together as one System.
This version of System 2 will support up to eight System 2 units for a total of 16 doors.
More users can be stored in memory if you do not use networking. This is because each unit
must set aside more memory for network operations, thus reducing the memory available for
users.
Enter 1 (YES) at the prompt to allow a unit to be networkable (as either a master or slave).If
your system is a “stand-alone” unit (a one or two door system), and you will not be expanding
the system in the future, answer [2], [No].
The VDT will display the following instructions:
1=Yes,2=No
Allow Networking? [2]
Select Yes or No and press ENTER.
Memory Error
If your System does not accept the above information, you may see a memory error prompt.