PC/VDT PROGRAMMING - BATCH ENROLL KEYPAD CODES
9-215
System 2 Installation / Programming Manual
Note: Although the display states the Option is Not Active, the output(s) have been assigned to the selected schedule.
However, it will not activate until the Second Door has been turned ON. Proceed to Option #13 to turn this Option ON.
The unit assigns this output to the schedule for those customers who wish to upgrade a one-door system (2003) to a two-
door system (2016) in the future, but do not wish to re-program the outputs.
Additional Outputs
When a valid code is entered, the door relay for that Port will be activated. In addition to this
activation, you might want other outputs to be activated to sound an alarm, trip a dialer, or send
some other signal. There are four such outputs from which to choose. The Port programming
section of this manual details the physical properties of the outputs. Any, all, or none of these
outputs may be activated by a valid code entry if the Second Door is activated. Refer to Option
#13 to purchase this option.
The VDT will display the instructions:
Assign These Output(s)
to User ID
1=Aux Relay 1
2=Aux Relay 2
3=Voltage Output 1
4=Voltage Output 2
0=None
Outputs [----]
At the Outputs [----] prompt, enter the desired output(s), if any, then press ENTER.
Example: If you select 1 (Auxiliary Relay 1) and 3 (Voltage Output 1) after someone in this
group enters a valid code or uses a valid Card the door will be activated and the Auxiliary Relay
#1 and Voltage Output #1 will activate.
If you select any of these Outputs and you have not activated the Second Door the VDT will
display:
Option Not Active
Install in Option 13
Press Any Key