LCD PROGRAMMING - PORT CONFIGURATION
8-81
System 2 Installation / Programming Manual
1=Program Ports þþþþ
Select Option [ _ ]
Port Configuration (Option #5)
The System 2 has two Ports. Each Port consists of the following:
“C Form” relay for door control
Keypad input
Reader input (Data Chip, Mag-Stripe, Wiegand, Proximity, or Bar Code)
Request-To-Exit (RTE) input
Door Ajar / Forced Entry input
Zone Input
In this option you can program how long the door relay will activate in response to a valid code
entry, and which schedule, if any, will automatically activate the door relay.
-OR-
Set the ports to Any Card/Chip Mode. In this mode, any Corby Cards or Data Chips will
activate any of the doors, regardless if the card or chip is programmed into the unit. All
someone needs is a Corby card or data chip and the door can be accessed. This should only be
used in minimal security applications where security is not strictly enforced. In other words,
this can be classified as an unlimited users mode. In this mode, the System 2 functions more as
a privacy device than as a security device.
Selecting the Desired Mode of Operation
The LCD will scroll the following instructions:
Scrolling Options: 2=Any Card/Chip Mode
0=Quit
At the Select Option [ _ ] prompt, enter the desired mode of operation and # (enter).
If you select 2=Any Card/Chip Mode, skip to Selecting Any Card/Chip Mode. If you select
you select 1=Program Ports you will see the following prompts: